- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0001000000000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Hirulkar, Nitesh (1)
-
Jagatap, Shraddha (1)
-
Nassar, Sayed A (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract This study investigates the effect of autoclave curing variables on the glass transition temperature of and the degree of cure and strength of epoxy film adhesive single lap joints (SLJs) under static tensile shear loading. Studied autoclave variables include the cure temperature, cure pressure, temperature, and pressure ramp rates on the glass transition temperature as well as the cure time duration. Test joints are made of Aluminum substrates that are autoclave-bonded using epoxy film adhesive (AF163-2k). For each variable combination of the autoclave process, the corresponding glass transition temperature of cured Epoxy film adhesive is obtained using Dynamic Mechanical Analysis (DMA-Q800). Test data are generated for both baseline joints [uncycled] as well as for joints that have been heat-cycled in an environmental chamber after initial autoclave bonding. Results show a strong correlation between the autoclave process variable combinations and the corresponding glass transition temperature bond strength, and the failure mode of test joints.more » « less
An official website of the United States government
